Blower door testing

Blower Door Test Preparation for Florida New Homes

How a new house should be left on test day, so the reading measures the shell the way the Florida energy code sets out.

Hallway of a newly finished house

Getting a new house ready for its test

Big Bend Services, Inc. tests new homes across the Florida Panhandle under the code's test conditions, and the builder, superintendent or owner sets the house up before we arrive.

Book the test once every opening through the shell is made. Call (850) 819-6031 with any question about the conditions, Monday to Friday from 7:00 AM to 4:00 PM. The same set-up applies on the day of a retest.

Newly built single-story home with fresh sod and a new driveway

Test-day conditions

How the house is left for the test

Each condition is there so the test measures leaks in the shell and nothing else. Where one does not apply, such as a house with no fireplace, skip it.

  • Windows and exterior doors closed, not sealed

    Closed, so an open sash is not counted as a leak. Not taped or covered, because air that slips past a closed window or door is part of what the shell leaks.

  • Fireplace and stove doors closed

    An open fireplace or stove door is a straight path up the flue.

  • Exhaust, intake and flue dampers closed

    Dampers on fans, fresh air intakes and flues are shut, and left as they are in normal use.

  • Interior doors open

    Where interior doors are hung, they stand open so every room is at the same pressure and the house is measured as one space. A doorway with no door yet is already open.

  • Heating and cooling off

    A running air handler moves air around the house and pushes against the pressure the test fan is holding. Turn it off at the thermostat before the fan goes in.

  • Registers fully open

    Supply and return registers are open where they are installed, so the ducts connect to the rooms the way they do in use. Take off any tape, plastic or covers put on them to keep out drywall dust.

Blower door fan sealed into the front doorway of a new house, seen from outside

The attic and an attached garage on test day

With a vented attic, the attic is outside the test and the ceiling below it is part of the shell. The attic hatch or pull-down stair is closed like any other opening in that ceiling, with a pull-down stair folded up fully and its panel sitting flat in the frame.

When the attic is sealed and insulated at the roof deck, it is opened to the house for the test and measured with it.

An attached garage that is not heated or cooled is outside the test. The wall and door between the garage and the living area are part of the boundary, so that door stays closed while the fan runs.

Blower door fan set in a red panel across the front doorway of a new house

The day before

Loose ends to check the day before

  • Openings waiting for a line

    An opening cut for a pipe, wire or line set that has not been run yet is still open through the shell. Run the line or close the opening.

  • Vents outside

    Exhaust and dryer vents have their outside caps or hoods on.

  • Windows latched

    Every window is shut and latched, including the ones upstairs and in closets.

  • Fans and appliances off

    Bath fans, the range hood and the dryer are not running.

  • Access panels

    Panels for tub valves, a water heater closet or an attic knee wall are in place and closed.

  • Floor openings

    On a raised floor, openings cut in the subfloor for pipes and ducts are closed around the pipe or boot.

  • A clear doorway

    One exterior doorway is clear of materials for the fan and its frame.

  • Temporary openings

    A window left out for deliveries, or a gap left for a temporary power cord, is closed up.

  • Crawl space access

    On a raised floor over a vented crawl space, the crawl space hatch is closed like the attic hatch.

  • If the house will not be ready

    If an opening is still to be made, or the conditions cannot be set on the day, call before the test date and a new date is set.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it
Blower door fan in a red panel beside a doorway with a gauge on a tripod

What to expect

From booking to result

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    A fan in an exterior doorway holds the house at the test pressure while the air leakage is measured.

  4. 4

    If it is over

    The leaks are corrected, and the house is tested again under the same conditions.

Get a Quote

Blower door fan sealing the front door of a new house, seen at an angle

FAQ

Test preparation questions

Have another question? Call (850) 819-6031.

Should the drain traps have water in them?
Yes. A sink, tub or shower drain with a dry trap is an open path to the plumbing vent through the roof. Run a little water down each drain before the test. Toilets hold their own water once they are set.
Can the crew keep working in the house during the test?
Work that does not open an exterior door or window, and does not run a fan or blower, can carry on. An exterior door opened while the test fan is running breaks the pressure the test depends on.
Do the bath fans and range hood need to be installed?
Yes. Each one makes an opening through the shell, and the test counts only the openings that exist on the day it runs.
Do paint and flooring need to be finished for the test?
No. Paint, flooring, trim, cabinets and countertops do not change the reading.
Should the fresh air or ventilation system be off?
Yes. A ventilation fan that runs on its own moves air through the shell. Turn it off and leave its damper closed.

Get a quote

Request a Blower Door Test

Send the address and the date the house will be ready, and the office will follow up.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Empty garage of a newly built house with a white door and a water heater

Your information is used to respond to this request. See our Privacy Policy.