Mon-Fri, 7:00 AM-4:00 PMCall Big Bend Services(850) 819-6031

Malone, Jackson County

Blower Door Testing in Malone, Florida

For builders with more than one house in Malone, and for owners building a single custom house.

Blower door fan set in a red panel across the front doorway of a new house

Blower door tests on new Malone houses

Big Bend Services, Inc. runs blower door tests on new houses in Malone, ZIP 32445. Each house is measured against the Florida energy code limit of 7 air changes per hour at 50 pascals for Climate Zone 2.

Builders, superintendents and owner-builders can book. Call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or send the form.

Blower door fan sealing the front door of a new house, seen at an angle

Several houses

Booking tests for several Malone houses

A builder with a run of houses can send them together. Each is tested on its own and gets its own result.

  • Details per house

    For every house: the address, the permit number, the ready date and who to call on site.

  • Houses sent as they firm up

    A house can be sent once its ready date is known, without waiting for the rest of the list.

New single-story house with the outside finished and the yard not yet landscaped

Keeping several tests on track

If a ready date slips, call the office and a new test date is set.

Book each house once the last opening through its walls, ceiling and floor is made. Finish work can carry on around the test, and booking ahead of it leaves room for a retest on any house that needs one.

Blower door fan sealed into the front doorway of a new house, seen from outside

Owner-builders

Building one custom house in Malone

An owner building a single house books the same test a builder does, with the same details, and the timing depends on when your trades finish their work through the shell.

Ask each trade whose work crosses the outside walls, the ceiling below the attic or the floor to tell you when their part is done.

  • A contact on the day

    Give your own number, or name someone who can open the house.

Empty laundry room with washer hookups in a newly finished house

The attic

Vented or sealed attic on a custom Malone house

  • Vented attic

    The ceiling is the line. Every light, fan, boot and hatch through it is an opening.

  • Attic sealed at the roof deck

    The roof deck is the line, and the attic is opened to the house for the test, with its hatch or door left open while the fan runs.

Hallway of a newly finished house

Custom features

Custom details that add to the shell

Each one adds joints or openings that are part of what the fan measures.

  • Vaulted or cathedral ceilings

    The roof framing becomes the boundary, so every light and vent cut into it counts.

  • A second floor over part of the house

    Where a lower roof meets an upper wall, the framing between floors is part of the shell.

  • Large windows and glass doors

    More frame to seal around each rough opening.

  • Outdoor kitchens and living areas

    Gas, water and power lines through the outside wall to reach them.

  • Skylights

    The curb and the shaft through a vented attic are part of the boundary.

  • Fireplace flues

    The chase around a factory-built flue, where it passes through the ceiling.

  • A wood stove

    Its pipe through the ceiling or wall is one more penetration.

  • A central vacuum

    Its exhaust runs through an outside wall.

Empty kitchen of a newly built house

Test day

How each house is left

Every house on the list is set up the same way: outside windows and doors closed without tape, dampers shut, interior doors open, registers open, and heating and cooling off.

  • The fan

    It is fitted in an exterior doorway and holds the house at the test pressure while the leakage is measured.

  • Plumbing traps

    Run water into any drain that has not been used, since an empty trap is an open pipe to the vent stack.

  • The door from the garage

    Shut and latched.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Over the limit

If one house reads over 7

That house has its leaks corrected and is tested again under the same conditions. The size of the gap to 7 gives a sense of how much sealing that house needs.

  • Booking the retest

    Send the date the corrections will be done for that address.

Hallway of a new house with an attic access hatch in the ceiling

Other services

Other work for the same houses

Gutters, garage doors and wire shelving come from the same company.

  • One call per job site

    List the other work for each address when you send the test details.

Clipboard, pencil and tape measure on a pickup tailgate in the driveway of a brick ranch house
Blower door fan in a red panel beside a doorway with a gauge on a tripod

What to expect

How the tests are booked

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built white farmhouse-style home with a metal porch roof and fresh sod

FAQ

Malone blower door test questions

Have another question? Call (850) 819-6031.

Does each house need its own site contact?
No. If the same superintendent opens every house, one name and number is enough.
Is a model home tested?
Yes, if it is newly built. Being used as a model does not change the test or the limit.
Does a two-story house get tested floor by floor?
No. The whole house is tested at once, with interior doors open so both floors share the same pressure.
Do slab and raised-floor houses test the same way?
Yes. The fan and the limit are the same. On a raised floor, the floor is part of the shell, so pipes and wires through it count. On a slab, the joint where the walls meet the slab is part of it.
Does a house with a gas range need anything different?
No change to the set-up. The gas line through the wall or floor is one more penetration, so it needs to be in before the test.

Get a quote

Request a Blower Door Test in Malone

Send the details for each Malone house: address, permit number, ready date and site contact.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Empty bedroom of a newly finished house

Your information is used to respond to this request. See our Privacy Policy.