Mon-Fri, 7:00 AM-4:00 PMCall Big Bend Services(850) 819-6031

Marianna, Jackson County

Blower Door Testing and Retests in Marianna, Florida

For a new Marianna house that has to meet the energy code air leakage limit, including one whose first reading came back high.

Blower door fan set in a red panel across the front doorway of a new house

Blower door test for a new house in Marianna

Big Bend Services, Inc. runs blower door tests on newly built houses in Marianna, ZIP codes 32446 and 32448. The Florida Building Code, Energy Conservation, 8th Edition (2023), caps air leakage in a new house at 7 air changes per hour at 50 pascals in Climate Zone 2, and all of Jackson County is in that zone.

Call (850) 819-6031, Monday to Friday from 7:00 AM to 4:00 PM, or send the form. Tests are booked through our office in Wewahitchka.

Newly built single-story home with fresh sod and a new driveway

Over the limit

When a Marianna house reads over 7

The result is one number for the whole shell.

  • Leaks corrected first

    The leaks are corrected before the house is tested again. A test run while sealing is still under way would measure a house in the middle of changing.

Hallway of a newly finished house

Before the second test

Openings to look at before a retest

Air leaves a new house through the openings made while it was built.

  • Tops of interior walls

    Wires and pipes run up through the top plate into a vented attic. Each opening left there joins the wall cavity to the attic.

  • The attic access

    A hatch or pull-down stair that does not sit tight in its frame passes air all the way around its edge.

  • Ceiling fixtures

    Recessed lights, fan boxes and smoke alarm boxes cut into a ceiling that has the attic above it.

  • Duct boots

    The gap between a supply or return boot and the drywall cut around it.

  • Lines leaving the house

    Refrigerant lines, the condensate drain, water and gas lines, and cable entries through an outside wall.

  • Tubs and showers on outside walls

    The framing behind a tub set against an exterior wall can be open to the attic above.

  • Chases and soffits

    A dropped soffit over the kitchen cabinets or a chase for a flue can be open to the attic at the top.

  • The door from the garage

    With an unheated, uncooled attached garage, the shared wall and the door into the living area are part of the measured boundary.

Blower door fan sealed into the front doorway of a new house, seen from outside

Between the two tests

Getting the house ready for its second test

  • The test-day state

    Windows latched but not taped, fireplace doors and all dampers closed, interior doors open, registers open, and the heating and cooling off, just as for the first test.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Additions and alterations in Marianna

The air leakage test is written for new houses. The code makes an exception for additions and alterations that make up less than 85 percent of the building thermal envelope, so a single added room or a remodel of part of a house can fall outside it. Your building official decides whether the exception covers a given project.

Blower door fan sealing the front door of a new house, seen at an angle

Booking with room for a retest

The code allows the test any time after every penetration of the thermal envelope exists. Booking at that point, while paint, flooring and trim are still going in, keeps a slot on the schedule for sealing and a second test if the first number is high.

Send the street address, the permit number, the ready date and the name and phone number of whoever will be on site. If the ready date slips, call the office and a new test date is set.

A builder with more than one house can book them together. Each house is tested on its own and gets its own result, so one high reading never holds up a house that came in under the limit.

Blower door fan set up in a hallway doorway of a new home

Other services

More work on the same new house

Big Bend Services, Inc. also installs gutters, garage doors and wire shelving, and any of them can be raised on the call that books the test.

  • Gutters

    Seamless gutters and downspouts, with new construction scheduled around the builder.

  • Garage door and shelving

    A new garage door and opener, and wire shelving for the closets, pantry and laundry room.

New seamless gutter run installed along a residential roofline
Newly built white farmhouse-style home with a metal porch roof and fresh sod

What to expect

From booking to a result

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built two-story home with fresh sod and a new driveway

FAQ

Marianna blower door test questions

Have another question? Call (850) 819-6031.

Can the retest be run before cut drywall is patched?
No. A cut left open in a wall or ceiling is an opening, and the fan will count it.
How far over the limit is a reading of 8.4?
On a house with 16,000 cubic feet inside, 8.4 means about 2,240 cubic feet per minute of leakage at 50 pascals, against about 1,870 at 7. Roughly 370 has to come out.
Does a high first reading hold up the finish work?
No. Paint, floors, trim and cabinets have no effect on the number, so they can keep going. Avoid closing off anything that still needs sealing, such as a ceiling fixture that has not been sealed around.
Is the attic part of a Marianna test?
Not with a vented attic. An attic sealed and insulated at the roof deck is opened to the house for the test and measured with it.
Where does the fan go?
In an exterior doorway. It holds the house at the test pressure while the leakage is measured.

Get a quote

Request a Blower Door Test in Marianna

Send the Marianna address, the permit number and the ready date, or the date corrections will be done for a retest.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Hallway of a new house with an attic access hatch in the ceiling

Your information is used to respond to this request. See our Privacy Policy.