Blower Door Testing in Jacob City, Florida

For a new house going up in Jacob City: the point in the build to book the air leakage test, and what the test does.

Blower door fan set in a red panel across the front doorway of a new house

Air leakage tests for Jacob City houses

Big Bend Services, Inc. tests newly built houses in Jacob City for air leakage under the Florida energy code. Jacob City addresses share ZIP 32431 with Cottondale, so give the full street address when you book.

The limit for Climate Zone 2, which covers all of Jackson County, is 7 air changes per hour at 50 pascals. Call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or use the form.

Hallway of a newly finished house

When to book

The point in a Jacob City build to book the test

The code allows the test at any time after all penetrations of the building thermal envelope have been created. A penetration is any opening made through the outside walls, the ceiling below a vented attic, or the floor, for a pipe, wire, vent, duct or fixture.

  • Plumbing

    Drain, vent and supply lines through the walls, floor and ceiling, including the hose bibs and the vent stacks up through the ceiling.

  • Electrical

    Boxes in outside walls and in the ceiling under the attic, exterior lights and outlets, and the service entry.

  • Heating and cooling

    Duct boots at the ceiling or floor, plus the refrigerant lines and condensate drain to the outside.

  • Vents

    Bath fans, a ducted range hood and the dryer vent, each with its run to the outside.

  • Low-voltage and gas

    Cable, internet, doorbell and alarm wiring that enters the house, and any gas line through an outside wall.

  • Drywall and the attic access

    The outside walls and the ceiling below the attic closed up, with the hatch or pull-down stair framed and hung.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Before you call

A last look before giving us the ready date

  • The hatch

    It closes flat on its stop and does not rock.

  • The garage wall

    With an attached garage, the door into the house is hung and the shared wall is closed up.

  • Windows and outside doors

    All hung, with weatherstripping on the doors.

  • Plumbing traps

    Water in every trap, so no drain is an open pipe to the vent stack.

Empty garage of a newly built house with a white door and a water heater

The boundary

Spaces inside and outside the test

The fan measures the thermal envelope around the heated and cooled rooms.

  • A vented attic

    Outside. The ceiling below it is the boundary.

  • An attic sealed at the roof deck

    Inside. It is opened to the house for the test and measured with it.

  • An unheated, uncooled attached garage

    Outside. The wall and door between it and the living area are counted.

  • Porches and carports

    Outside. The wall and doors between them and the house are the boundary on that side.

  • Detached buildings

    Not part of the test. The fan measures only the house it is set up in.

  • A room over the garage

    Inside once it is heated and cooled, with its floor over the garage on the boundary.

Blower door fan sealed into the front doorway of a new house, seen from outside

What the fan does

A fan set in an exterior doorway holds the house at 50 pascals against the outdoors while the leakage is measured. However much air the fan must move to keep that pressure steady is the same amount getting through the shell.

That airflow, compared with the volume of air in the house, gives the air changes per hour. The whole house is read at once, which is why interior doors stand open and the result comes out as one number.

Paint, flooring, trim and cabinets have no part in it.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Test day

How the house is left for the fan

The code sets out the condition of the house during the test. Where a condition does not apply, such as a house with no fireplace, it is skipped.

  • Windows and outside doors

    Closed, but not sealed or taped.

  • Fireplace and stove

    Doors closed.

  • Exhaust, intake and flue dampers

    Closed.

  • Interior doors

    Open, where they have been hung.

  • Heating and cooling

    Off.

  • Supply and return registers

    Fully open, where installed.

Blower door fan sealing the front door of a new house, seen at an angle

After the test

If the reading is over 7

A reading over 7 means the leaks are corrected and the house is tested again under the same conditions.

  • Dates that slip

    If the ready date for either test slips, call the office and a new date is set.

Blower door fan set up in a hallway doorway of a new home

Booking

Booking a test for a Jacob City house

Tests are booked through our office in Wewahitchka, by phone or the form, with the address, the permit number, the ready date and who to call on site.

  • More than one house

    Several houses can be booked together, including houses in nearby towns. Each is tested on its own and gets its own result.

  • Other services

    Gutters, a garage door and wire shelving for the same house can be raised on the same call.

New single-story house with the outside finished and the yard not yet landscaped
Newly built stucco home with a white garage door and a new concrete driveway

What to expect

How the test is booked

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Empty living room of a newly finished house

FAQ

Jacob City blower door test questions

Have another question? Call (850) 819-6031.

Do recessed lights count as openings?
Yes, when they sit in a ceiling below the attic. The housing and the gap around it are both openings in the shell.
Does a wood stove need its pipe in before the test?
Yes. The flue collar and the gap where the pipe leaves the house both sit on the boundary, so the stove is set and its pipe run first.
Does the dryer vent need its outside hood?
Yes. The hood and its flap close the duct when the dryer is off. Without them, the duct stays open to the outdoors.
Does the house need its gutters before the test?
No. Gutters hang on the fascia outside the house and are not part of the shell, so they can go on before or after the test.
How much leakage does the limit allow on a small house?
About 1,300 cubic feet per minute at 50 pascals for a 1,400 square foot house with 8-foot ceilings, which holds about 11,200 cubic feet. The 50 pascal test pressure is about 0.2 inches of water column.
Are there houses the test does not apply to?
Additions and alterations under 85 percent of the building thermal envelope are an exception in the code. A newly built house is tested.

Get a quote

Request a Blower Door Test in Jacob City

Send the full Jacob City street address, the permit number and the ready date.