Blower Door Testing in Sneads, Florida

For builders and owners getting a new Sneads house ready for its air leakage test under the Florida energy code.

Blower door fan set in a red panel across the front doorway of a new house

A blower door test for your Sneads house

Big Bend Services, Inc. runs air leakage tests on new houses in Sneads, ZIP code 32460. The Florida energy code limit for Climate Zone 2 is 7 air changes per hour at 50 pascals, and the code also sets how the house must be left while it is measured.

Builders, superintendents and owners of a newly built house can book it. Call (850) 819-6031 on a weekday between 7:00 AM and 4:00 PM, or use the form.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Test day

Setting up a Sneads house for the test, room by room

  • Kitchen

    Range hood damper closed.

  • Laundry

    Dryer vent flap closed at the wall, whether or not the dryer is in yet.

  • Bathrooms

    Exhaust fan dampers closed. Windows shut and latched.

  • Living areas

    Fireplace or stove doors shut and the flue damper closed. Outside doors shut and latched, with no tape or plastic over them.

  • Bedrooms and closets

    Doors propped open so every room shares the same pressure. Supply registers fully open.

  • Hall and attic access

    Hatch or pull-down stair seated in its frame, unless the attic is sealed at the roof deck.

  • Equipment closet

    Heating and cooling off at the thermostat. Return grille open.

  • Outside

    Any fresh air intake damper closed, and hose bibs, the dryer vent hood and the line set entry in place with no gap left open around them.

Blower door fan sealed into the front doorway of a new house, seen from outside

Small things that change the number

A drain with no water in its trap is an open pipe to the vent stack and the roof. Run water into any sink, tub, shower or floor drain that has not been used yet, so each trap is full.

An opening cut for a line that has not been run yet, or an empty ceiling box with a gap around it, is open to the attic or a wall cavity while the fan runs.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Before test day

Places worth a look in the days before

  • Top plates

    Openings for wires and pipes through the tops of the walls, seen from the attic.

  • Boots and boxes

    The seam where each duct boot and ceiling box meets the drywall.

  • The hatch

    A stop for it to rest on and weatherstripping around it.

  • The door from the garage

    Weatherstripping and a threshold, since it is part of the boundary with an unconditioned garage.

Blower door fan sealing the front door of a new house, seen at an angle

Several houses

Builders testing more than one house in Sneads

A builder with several houses going up can book them together. Each house is still tested on its own, with its own set-up, its own fan run and its own result.

The room-by-room check above is worth handing to whoever sets up each house, so every house on the list is left the same way.

  • Details for each house

    The address, permit number, ready date and the person to call on site, for every house on the list.

  • A date that slips

    Call, and that house alone gets a new test date.

Empty living room of a newly finished house

When the house is ready to book

The code allows the test at any point after every opening through the thermal envelope has been made.

Low-voltage runs count the same as a pipe or duct, so cable, doorbell and alarm lines through an outside wall should be in too. The drywall on the outside walls and on the ceiling below a vented attic is part of what holds the air in, so it has to be up as well.

Blower door fan set up in a hallway doorway of a new home

Over the limit

If a house reads over 7

The result is one number for the whole house. Over 7, the leaks are corrected and the house is tested again, set up the same way as the first time. Before calling for the retest, run through the room-by-room check again, because anything left out of place would count against the second reading just as it would the first.

  • The size of the miss

    A reading just over 7 points to a smaller amount of sealing than one well above it.

  • The retest booking

    Send the date the corrections will be done.

New single-story house with the outside finished and the yard not yet landscaped

Other services

The rest of the work on a new house

Gutters, a garage door and wire shelving for closets and the pantry are handled by the same company.

  • Booked together

    Mention the other work when you book the test, and it can be quoted for the same address.

Clipboard, pencil and tape measure on a pickup tailgate in the driveway of a brick ranch house
Empty kitchen of a newly built house

What to expect

Booking the test, start to finish

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built stucco home with a white garage door and a new concrete driveway

FAQ

Sneads blower door test questions

Have another question? Call (850) 819-6031.

What about a pet door?
A pet door in an outside door or wall is an opening in the shell. Its flap is closed for the test, and the gaps around it count.
What changes with an attic sealed at the roof deck?
The attic hatch or door is left open so the attic joins the rooms, and any supply register in the attic stays open with the rest.
Can the test go ahead before the cabinets are in?
Yes. Cabinets and countertops are finishes and do not change the reading.
Does a house with no fireplace skip that step?
Yes. A condition that does not apply, such as a fireplace, a stove or a fresh air intake the house does not have, is left out.
Why does the air handler have to stay off?
Its blower stirs air through the ducts and rooms while the test fan is trying to hold one steady pressure, which would throw off the measurement.
Does the big garage door need to be shut?
No. It makes no difference for an unheated, uncooled garage, since the garage is outside the test. The door from the garage into the house is the one that has to be shut and latched.

Get a quote

Request a Blower Door Test in Sneads

Send each Sneads address with its permit number, ready date and site contact.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Empty laundry room with washer hookups in a newly finished house

Your information is used to respond to this request. See our Privacy Policy.