Parker, Bay County

Blower Door Testing in Parker, Florida

Air leakage testing for new houses in Parker, booked well ahead of your deadline.

Blower door fan set in a red panel across the front doorway of a new house

Blower door tests on new Parker houses

The Florida energy code requires new houses to be tested for air leakage, and Big Bend Services, Inc. runs that blower door test in Parker, ZIP code 32404. Parker tests are booked through our office at 511 S Highway 71 in Wewahitchka.

Call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or use the form.

Blower door fan sealing the front door of a new house, seen at an angle

The test

What happens when the fan runs

The test gives one number for the whole house: how leaky the shell is compared with the size of the house.

  • A fan in the doorway

    The fan is fitted into an exterior doorway, with the rest of the opening closed off around it, so it is the only planned path for air to move in or out.

  • The house held at pressure

    The fan runs until the difference in pressure between inside and outside reaches 50 pascals, and keeps it there.

  • Fan airflow equals leak airflow

    To keep that pressure steady, the fan has to move as much air as the leaks let through, so measuring the fan measures the leaks.

  • The number

    That airflow is set against the volume of the house to give air changes per hour. Section R402.4.1.2 of the Florida Building Code, Energy Conservation, 8th Edition (2023), sets the limit for new houses at 7, and Bay County is in Climate Zone 2, where it applies.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Why the house is set up a certain way

Because the fan measures every path air can take, the house has to be set so only the leaks in the shell are counted. Interior doors are open so every room reaches the same pressure. The heating and cooling equipment is off and the registers are fully open, so the duct system neither moves air of its own nor holds a closed-off pocket.

Windows and exterior doors are shut but not taped, and exhaust, intake and flue dampers and fireplace doors are closed, so the house is measured the way it is built to be used.

Blower door fan sealed into the front doorway of a new house, seen from outside

Before the fan goes in

Openings to finish before a Parker test

The fan measures every gap in the shell, finished or not, so these need to be in place and closed around before the date.

  • Hose bibs and outdoor outlets

    Each one passes through an outside wall, and the gap around it counts.

  • The line set

    The copper lines and drain running out to the air conditioning unit go through the wall.

  • Vent hoods

    Bath fans and the range hood vent out through the wall or roof, so their ducts need to be run.

  • The attic opening

    A hatch or folding stair that closes snugly against a seal.

  • Ceiling lights and fans

    Can lights and fan housings in the ceiling below the attic, with the edges closed to the drywall.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Less obvious paths

Framing that can carry air out of a Parker house

Not every leak is at a pipe or a wire. Some paths are part of the framing and are hidden once the drywall is hung.

  • Air handler closet

    A closet framed around the air handler, with a return built into it, can open into the attic or the wall cavities around it.

  • Soffits and chases

    A framed soffit above the kitchen cabinets, or a chase for ducts or a flue, can open straight into the attic.

  • Fireplace chase

    The framed box around a fireplace flue can connect the living space to the attic.

  • Between floors

    On a two-story house, the band of framing between floors at the outside walls is a path for air unless it is sealed.

New single-story house with the outside finished and the yard not yet landscaped

Attics and garages on a Parker plan

The fan only measures the heated and cooled part of the house. A vented attic is outside that, and the ceiling below it is the boundary. When the attic is sealed and insulated at the roof deck, it is opened to the house and measured along with the rooms. An attached garage that is not heated or cooled stays outside, and its shared wall and door with the house are measured.

Empty garage of a newly built house with a white door and a water heater

Booking ahead

Set the Parker test date ahead of your deadline

The test can run as soon as the last opening through the shell is made. Booking for that point, rather than the last week before you need the result, is what leaves room for a second try.

  • Room to correct

    If the first reading is over 7, the leaks are corrected before a retest, and that work is easier before the finish trades are through.

  • Finishes carry on

    Paint, flooring, trim and cabinets do not change the reading, so they can go in after the test and testing early does not hold up the rest of the build.

  • A date that slips

    If the shell will not be done on the date you gave, call the office and a new date is set.

  • The retest date

    Once the corrections are finished, a retest is booked the same way as the first test.

Empty living room of a newly finished house

Booking one Parker house or several

When a builder has more than one Parker house due at about the same time, book each one as its own shell closes rather than holding them all for one date at the end. Each house is tested separately, so a house that is ready early can be tested early. For every house, send the address, the permit number, the date the shell will be done and who to call on site.

Blower door fan set up in a hallway doorway of a new home

Crews inside during the test

Anyone working inside the house should stay put or step out before the fan starts, rather than coming and going while it runs, since an opened door changes the reading. Work that needs a door held open, like carrying in flooring or cabinets, can pick up again as soon as the test is over.

Newly built two-story home with fresh sod and a new driveway

Owner-builders in Parker

An owner building under their own permit books the test the same way a builder does. The date to aim for is the day your plumber, electrician and air conditioning installer have all made their last openings through the walls and ceiling, so ask each of them for that day before you book.

Hallway of a new house with an attic access hatch in the ceiling

Additions in Parker

For an addition or alteration that makes up less than 85 percent of the building shell, the code does not require the test. A project at or above that share is tested the same way as a new house, with the same limit and the same setup, and it is booked through the same office with the same details.

Empty bedroom of a newly finished house
Newly built white farmhouse-style home with a metal porch roof and fresh sod

What to expect

What happens after you book in Parker

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built single-story home with fresh sod and a new driveway

FAQ

Parker blower door questions

Have another question? Call (850) 819-6031.

Does the doorway for the fan need its door hung?
The door frame needs to be in. The fan is set into an exterior door opening with that door swung open, and the frame gives it something to seal against.
Is a house on a slab tested any differently?
The test is the same. On a slab, the concrete is the floor of the shell, and the places to look are where plumbing comes up through it, such as under tubs and behind toilets.
Can a temporary construction door stand in for the real one?
No. The finished exterior doors need to be hung, because the leakage around their frames and sweeps is part of what gets measured. A panel or a construction door leaves gaps the finished door would not.
Why 50 pascals?
It is a fixed test pressure, equal to 0.2 inches of water column. Using one pressure for every house means a reading from one house can be set against the same limit as any other.
Is the reading affected by furniture?
No. Furniture and stored boxes sit inside the shell and do not change how much air gets through it.
Is a house over a crawl space tested differently?
The test is the same. With a vented crawl space, the floor above it is part of the boundary, so every pipe, duct and wire that drops through the subfloor is an opening that counts.

Get a quote

Request a Blower Door Test in Parker

Send the Parker address and the date the shell will be complete.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM