Blower Door Testing in Lynn Haven, Florida

Air leakage testing for newly built houses in Lynn Haven, booked for the point the shell is complete.

Blower door fan set in a red panel across the front doorway of a new house

Booking a blower door test in Lynn Haven

New houses going up in Lynn Haven as part of its rebuilding each need the air leakage test the Florida energy code sets. Big Bend Services, Inc. runs that blower door test for builders and owners in ZIP code 32444.

Call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or send the form.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Timing

The point in the build when a Lynn Haven house is ready

The code allows the test once every opening through the building thermal envelope has been made. The envelope is the boundary around the heated and cooled rooms: the outside walls, the ceiling below the attic and the floor.

  • Windows and doors set

    Every window and exterior door is in its opening, so the walls are closed.

  • Plumbing through the shell

    Drains, supply lines and roof vents are run wherever they leave the heated space.

  • Wiring through the shell

    The electric service, any gas line and the cable or phone lines are in, along with the wiring to outside fixtures.

  • Ducts and exhaust run

    Duct runs, the range hood duct and the dryer vent pass out through the wall or roof.

  • Ceiling closed

    The ceiling under the attic is on, with the attic access in and able to shut.

New single-story house with the outside finished and the yard not yet landscaped

What can still be unfinished

Paint, flooring, trim, cabinets and countertops have no effect on the reading, so the test does not wait for them. Booking at shell completion rather than at the end of the build leaves the finish work as a cushion, with time for corrections before the house is handed over. Booking before the last opening is made has the opposite problem: a vent or pipe added afterward is left out of the reading.

Blower door fan sealing the front door of a new house, seen at an angle

On the day

How a Lynn Haven house is left for the test

A fan fitted in an exterior doorway holds the house at the test pressure while the leakage is measured, and the code sets how the house is left while it runs.

  • Windows and outside doors

    Closed, but not sealed or taped.

  • Fireplace and stove

    Doors closed.

  • Dampers

    Exhaust, intake and flue dampers all closed.

  • Rooms

    Interior doors open where they have been hung.

  • Air conditioning and heat

    Switched off, with the supply and return registers fully open where installed.

Blower door fan sealed into the front doorway of a new house, seen from outside

Over the limit

If a Lynn Haven house reads over the limit

For new houses, the limit is 7 air changes per hour at 50 pascals, from section R402.4.1.2 of the Florida Building Code, Energy Conservation, 8th Edition (2023). All of Bay County is in Climate Zone 2, where that limit applies.

  • Corrected, then retested

    A house that reads higher has its leaks corrected, and the retest waits until every correction is finished.

  • Same setup

    The retest uses the same test-day conditions, so the two numbers compare directly.

  • A new date

    Call the office when the corrections are done and a retest date is set.

  • Only that house

    On a builder's list, a high reading on one house does not change the results of the others.

Blower door fan set up in a hallway doorway of a new home

Where air gets through

Openings to close before the first test

Gaps are easier to close before insulation and trim make them hard to reach.

  • Recessed lights

    Each can light set into the ceiling below the attic is an opening unless the fixture is built to be airtight and sealed to the drywall.

  • Duct boots

    Where a supply duct meets the ceiling or floor, the gap between the boot and the drywall leads into the attic or the space below.

  • Top plates

    Wires and pipes that rise through the top of a wall into the attic leave a gap around each one.

  • Tub and shower drains

    The opening cut in the floor under a tub drain is easy to miss once the tub is set.

  • Bath fan housings

    The edge between each fan housing and the ceiling drywall needs to be closed.

  • Air handler closet

    A closet framed around the air handler, with a return built into it, can open into the attic or the walls beside it.

  • Window and door frames

    The space between each frame and its rough opening, before casing covers it.

  • Soffits over the cabinets

    A framed soffit above the kitchen cabinets can open straight into the attic.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Additions to existing Lynn Haven houses

Not every project needs the test. The code makes an exception for additions and alterations that make up less than 85 percent of the building shell, so a new room or a remodel that stays under that share is not required to be tested. A project at or above that share is tested like a new house. Your building official decides where a project lands.

Newly built white farmhouse-style home with a metal porch roof and fresh sod

The rest of the house

Other work on a new Lynn Haven house

The same office books other services for new houses, and they can be arranged for the same Lynn Haven address.

  • Gutters

    Seamless gutters are scheduled around the builder, once the roof and fascia are finished.

  • Garage door

    A new garage door is measured to the opening, with a new opener if you want one.

  • Wire shelving

    Closets, the pantry and the laundry room can be shelved before move-in, supplied and installed by us.

Empty garage of a newly built house with a white door and a water heater

What to send for a Lynn Haven booking

Send the address, the permit number, the date the shell will be complete and the name of whoever can open the house. A builder can send several Lynn Haven houses together, and each is booked for its own date. Bookings go through our office at 511 S Highway 71 in Wewahitchka, and if the shell falls behind, call and a new date is set.

Empty living room of a newly finished house
Newly built stucco home with a white garage door and a new concrete driveway

What to expect

From booking to result in Lynn Haven

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built two-story home with fresh sod and a new driveway

FAQ

Lynn Haven blower door questions

Have another question? Call (850) 819-6031.

Does a metal roof change the test?
Not with a vented attic, where the ceiling below is the boundary. With the attic sealed at the roof deck, the deck becomes part of the boundary whatever roofing covers it.
Does a house with spray foam in the walls still need the test?
Yes. Every new house is tested, however it is insulated. Foam can close the gaps it covers, but an opening cut after it goes in, for a late wire or pipe, still lets air through.
Is a reading just above 7 close enough?
No. The code sets 7 as the maximum. A reading above it, by any amount, means corrections and a retest, so a small miss is handled the same way as a large one.
Can gutters and the garage door go on after the test?
Yes. Gutters sit outside the shell and have no bearing on the reading. On an unheated garage, the overhead door is outside the measured boundary too. The door between the garage and the house is inside it and should be hung first.
Do outdoor outlets and porch lights count as openings?
Yes. Every box for an outdoor light, outlet or doorbell passes through the outside wall, so the box needs to be in, with the gap around it closed.
Can one house be retested more than once?
Yes. The code puts no cap on how many rounds a house goes through. If a retest still comes back high, another round of corrections and another retest follow, and each round gives a fresh number.

Get a quote

Request a Blower Door Test in Lynn Haven

Send the Lynn Haven address and the date the shell will be complete.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Empty laundry room with washer hookups in a newly finished house

Your information is used to respond to this request. See our Privacy Policy.