Blower Door Testing in Springfield, Florida

Air leakage tests for new Springfield houses, with the setup the Florida code requires on test day.

Blower door fan set in a red panel across the front doorway of a new house

Getting a Springfield house ready for its blower door test

Big Bend Services, Inc. runs blower door tests on newly built houses in Springfield, in ZIP codes 32401 and 32404, booked through our office at 511 S Highway 71 in Wewahitchka. The Florida energy code sets how the house has to be left while the test runs.

To book, call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or send the form with the address, permit number, ready date and site contact.

Blower door fan set up in a hallway doorway of a new home

Test-day setup

How a Springfield house should be left for the test

The conditions come from section R402.4.1.2 of the Florida Building Code, Energy Conservation, 8th Edition (2023).

  • Windows and exterior doors shut, not sealed

    Nothing is taped over, so the reading includes the leaks around every sash and door frame.

  • Fireplace and stove doors shut

    An open firebox is a direct path up the chimney.

  • Dampers closed

    Exhaust, intake and flue dampers are built to close, and the test measures the house with them closed.

  • Interior doors open

    Where doors are hung, they stand open, closet doors included, so a closed bedroom does not hold back part of the house.

  • Heating and cooling off

    A running air handler moves air of its own and upsets the pressure the fan is holding.

  • Registers open

    Supply and return registers are fully open wherever they are installed, with any construction covers removed.

Blower door fan sealed into the front doorway of a new house, seen from outside

Finishes

What can wait until after the test

A Springfield house does not need to look finished to be tested.

  • Paint

    Paint on walls and ceilings has no effect on the reading.

  • Flooring

    Tile, wood and carpet go over a floor that is already part of the shell.

  • Trim

    Baseboard, door casing and crown molding can go in after the test.

  • Cabinets and countertops

    Kitchen and bath cabinets, and the tops that go on them, can be set later.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Why finishes and openings are treated differently

The layer that stops air in a house can include the drywall on outside walls and ceilings, the exterior sheathing, the windows and doors, and the sealant at joints. Anything that cuts through that layer changes the reading.

An outdoor light over the back door, a new vent or a line run outside after the test all count, and the code ties the test to the point when all of them exist.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

The day before

A walk-through the site contact can do

The person who sets the house up on the day is well placed to check it the day before.

  • Every exterior door hung and latching

    A door still waiting on its hardware leaves a gap the test will measure.

  • Pull-down attic stair shut tight

    The stair panel sits in the ceiling and needs to close fully and latch.

  • Boxes on outside walls

    Outlets and switches on exterior walls have their devices and cover plates on.

  • Temporary openings closed

    A hose run through a window or a cord through a door left ajar keeps the house open.

  • Dryer vent

    The vent runs through the wall with its outside hood and flap in place.

  • Plumbing under the sinks

    Where supply and drain lines come through the floor or an outside wall inside a cabinet, the gaps around them are filled.

Empty laundry room with washer hookups in a newly finished house

Less obvious paths

Framing that can let air out of a Springfield house

Some paths are built into the framing rather than cut by a trade, and they are hidden once the drywall is up.

  • Air handler closet

    A closet framed around the air handler, with a return built into it, can open into the attic or the wall cavities around it.

  • Soffits and chases

    A framed soffit above the kitchen cabinets, or a chase for ducts or a flue, can open straight into the attic.

  • Between floors

    On a two-story house, the band of framing between floors at the outside walls is a path for air unless it is sealed.

Torsion springs on the steel shaft above a closed garage door

Crews on site while the test runs

Painters or flooring crews working inside should stay put or step out before the fan starts, rather than coming and going while it runs, since an opened door changes the reading. Work that needs a door propped open, such as carrying in materials, can pick up again once the test is over.

Blower door fan sealing the front door of a new house, seen at an angle

Timing

Booking a Springfield test

  • Ahead of your deadline

    Booking early leaves slack before the date you need the result.

  • If the date slips

    Call the office and a new test date is set.

New single-story house with the outside finished and the yard not yet landscaped

What the test measures, and what it leaves out

A fan fitted in an exterior doorway holds the house at the test pressure, and the air it moves to hold that pressure is the air leaking through the shell. That flow, set against the volume of the house, is the reading.

A vented attic sits outside the test, and the ceiling below it is the boundary. An attic sealed and insulated at the roof deck is opened to the house and measured with it. An attached garage that is not heated or cooled is outside the test too, and the wall and door between it and the living area are part of the measured boundary.

Hallway of a newly finished house

Additions in Springfield

The code makes an exception for additions and alterations that make up less than 85 percent of the building shell, so those are not required to be tested. A project at or above that share is tested like a new Springfield house, with the same conditions on the day and the same limit.

Newly built stucco home with a white garage door and a new concrete driveway

The limit and what follows a high reading

New houses in Springfield, as in the rest of Bay County, are held to 7 air changes per hour at 50 pascals, and the county is in Climate Zone 2. A house that reads over the limit has its leaks corrected and is tested again with the same setup as the first test. Call when the corrections are finished and a retest date is set.

Empty kitchen of a newly built house
Empty garage of a newly built house with a white door and a water heater

What to expect

How a Springfield test is set up

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Empty bedroom of a newly finished house

FAQ

Springfield blower door questions

Have another question? Call (850) 819-6031.

Do the light fixtures need to be hung?
Fixtures on interior walls can go up later. Recessed lights in the ceiling below the attic cut through the shell, so their housings need to be in and sealed to the drywall.
Does the attic insulation need to be in?
Insulation slows heat, not air, so loose attic insulation does little to the reading. The number depends on how well the ceiling below it is sealed.
Can the air conditioner be installed but not started?
Yes. The ducts and the lines to the outdoor unit need to be in, because they pass through the shell. Whether the system has been started does not matter to the reading.
Does a skylight change anything?
A skylight is a window in the ceiling. Its frame and the shaft through the attic are part of the shell, so the gaps around them count the same as around any window.
Does a pet door count?
Yes. A pet door set into an exterior door or wall is an opening in the shell. Close its flap the way it sits when not in use.

Get a quote

Request a Blower Door Test in Springfield

Send the Springfield address and the date the house can be set up for the test.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Newly built white farmhouse-style home with a metal porch roof and fresh sod

Your information is used to respond to this request. See our Privacy Policy.