Mon-Fri, 7:00 AM-4:00 PMCall Big Bend Services(850) 819-6031

Apalachicola, Franklin County

Blower Door Testing in Apalachicola, Florida

How the attic and an attached garage fit into the blower door test on a new Apalachicola house.

Blower door fan set in a red panel across the front doorway of a new house

Blower door tests on new Apalachicola houses

Big Bend Services, Inc. runs blower door tests on newly built houses in Apalachicola, ZIP code 32320. The test measures the air that leaks through the boundary around the heated and cooled rooms, and on any plan the attic and the garage decide much of where that boundary runs.

Call (850) 819-6031, Monday to Friday, 7:00 AM to 4:00 PM, or send the form. Requests are handled from our office in Wewahitchka.

Blower door fan sealed into the front doorway of a new house, seen from outside

The attic

Two kinds of attic, two different boundaries

The plans show whether the attic is vented or sealed at the roof deck, and the office needs to know which when you book.

  • Vented attic

    Outside air moves through soffit, ridge or gable vents, and the attic is outside the test. The ceiling of the top floor is the boundary, and the attic hatch stays shut in its frame.

  • Attic sealed at the roof deck

    The roof deck, the gable walls and the joints where they meet the tops of the walls are the boundary. The attic is opened to the house for the test, with its hatch or stair left open.

  • Volume

    An attic sealed at the roof deck adds its space to the house when the reading is worked out.

Hallway of a newly finished house

Attached garage

Where an attached garage fits in the test

An attached garage that is not heated or cooled is outside the test, and the parts of the house that touch it are inside the boundary.

  • The shared wall

    The wall between the garage and the living area, including any pipe, wire or duct that passes through it.

  • The house door

    The door from the garage into the house, with its weatherstripping as installed.

  • A room over the garage

    When a heated and cooled room sits over the garage, its floor is part of the boundary.

  • The vehicle door

    The big door to the driveway is not measured.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

When the house attic and the garage attic meet

Where one roof runs over both the house and the garage, and the attic over both is vented, both attic spaces are outside the test. When the house attic is sealed at the roof deck but the space over the garage is vented, the wall that divides the two attic spaces becomes part of the boundary, up to where it meets the roof deck. On a plan that seals the whole roof deck, garage included, that dividing wall is no longer the line.

Empty garage of a newly built house with a white door and a water heater

Rooms built into the roof

A heated and cooled room built into the roof, with sloped ceilings and short knee walls, has attic space behind the knee walls. With a vented attic, the knee walls, the sloped ceilings and the strip of floor behind the knee walls are all part of the boundary, measured along with the flat ceilings elsewhere in the house. A plan like this carries more boundary than a flat ceiling, and all of it is counted.

Blower door fan set up in a hallway doorway of a new home

Edges of the boundary

Other spaces at the edge of the shell

Mechanical spaces, carports and rooms that hang over open air sit right against the shell.

  • Air handler in a vented attic

    The unit itself sits outside the test. Every duct boot and return that passes through the ceiling below it is an opening in the boundary.

  • A floor over open air

    A room that hangs over a porch or an open space below has its floor exposed to the outside, and that floor is part of the shell.

  • Attic stairs in the garage

    With both the garage and a vented attic outside the test, a pull-down stair in the garage ceiling joins two outside spaces and is not measured.

  • A carport

    It has no wall or door into the living area beyond the outside wall of the house, which is measured like any other.

Empty laundry room with washer hookups in a newly finished house

Test day

The rest of the set-up on test day

  • Outside openings

    Exterior windows and doors are closed but not sealed, and fireplace and stove doors are closed.

  • Dampers

    Exhaust, intake and flue dampers are shut.

  • Inside the house

    Interior doors stand open where they are installed, the heating and cooling is off, and supply and return registers are fully open.

Blower door fan sealing the front door of a new house, seen at an angle

Testing before or after the ceilings close

The code ties the test to the openings through the shell, not to the drywall. A test before drywall reads the shell as it stands that day, so on a vented attic plan the ceiling air barrier, and on a sealed attic plan the roof deck sealing, has to be complete by then. A test after drywall reads the finished shell. The builder chooses the point, and the booking is the same.

Empty living room of a newly finished house

Crews and the finish work around the test

Paint, flooring, trim, cabinets and countertops sit inside the shell and do not change the reading, so the finish trades can work before or after the test. On the day itself, crews can keep working as long as the house stays in its test-day set-up and no one uses the doorway the fan is fitted in until the test is over.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Scope

What an Apalachicola reading does not rate

The fan reads air leakage through the boundary and nothing more.

  • Insulation

    How much insulation is in the walls, the attic or the roof deck is a separate part of the energy code.

  • Windows

    Window and glass door energy ratings are not part of the reading.

  • Equipment

    The size and efficiency of the heating and cooling system are not rated.

Empty kitchen of a newly built house

Over the limit

If an Apalachicola house reads over 7

Section R402.4.1.2 of the 2023 Florida Building Code, Energy Conservation, allows a new house no more than 7 air changes per hour at 50 pascals in Climate Zones 1 and 2, and Table R301.1 places Franklin County in Climate Zone 2. A house over the limit has its leaks corrected and is tested again under the same conditions as the first test.

  • Book when the work is done

    The retest date goes after the corrections are finished.

  • The whole house again

    The retest reads the entire shell, not only the areas that changed.

  • Other houses

    On a job with several houses, only the one that read high is tested again.

New single-story house with the outside finished and the yard not yet landscaped

Booking

What to send with an Apalachicola booking

Four details set a test date, by phone or through the form. The owner of a new house can book directly, and a builder with several houses can send a line for each one.

  • Address

    The street address of the house.

  • Permit number

    The building permit for the house.

  • Ready date

    The date the house will be ready for the test.

  • Site contact

    The person who opens the house on test day, with any gate code or lockbox.

Newly built single-story home with fresh sod and a new driveway
Newly built white farmhouse-style home with a metal porch roof and fresh sod

Same county

Blower door tests in other Franklin County towns

Empty bedroom of a newly finished house

What to expect

How an Apalachicola test runs

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built stucco home with a white garage door and a new concrete driveway

FAQ

Apalachicola blower door questions

Have another question? Call (850) 819-6031.

Is a detached garage part of the test?
No. It shares no wall with the house, so nothing about it touches the shell. A covered walkway between the two does not change that.
Does a sunroom count toward the reading?
Yes, if it shares the heating and cooling of the house. A sunroom that is shut off from the house and has none sits outside.
What does air changes per hour mean?
It is how many times the air inside the house would be replaced by outside air in one hour at the test pressure.
Is a covered porch ceiling part of the boundary?
No. A covered porch is outdoors, ceiling and all. The house wall behind the porch, with its door and windows, is what gets measured.
What does 50 pascals equal?
50 pascals is 0.2 inches of water gauge, the same test pressure in another unit.
Does the reading show which part of the boundary leaked?
No. The result is one number for the whole shell.

Get a quote

Request a Blower Door Test in Apalachicola

Use the form to book a test on a new Apalachicola house, and the office will follow up.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Newly built two-story home with fresh sod and a new driveway

Your information is used to respond to this request. See our Privacy Policy.