Blower Door Testing in Blountstown, Florida

Blower door tests and retests on new houses in Blountstown.

Blower door fan set in a red panel across the front doorway of a new house

Testing and retesting new Blountstown houses

Big Bend Services, Inc. runs blower door tests and retests on newly built houses in Blountstown, ZIP code 32424. A retest is booked the same way as the first test, through the same phone number and form.

Call (850) 819-6031, Monday to Friday from 7:00 AM to 4:00 PM, or send the form. Requests are handled from our office in Wewahitchka.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

What a reading over 7 tells you

The reading is a single number for the whole shell, taken at the test pressure. It says how much air got through, not where it got through. A reading just over 7 and one well above it both mean the leaks are corrected and the house is tested again under the same conditions.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Same conditions

The test conditions, both times

The first test and the retest run under the same conditions, so the two readings can be compared.

  • Windows and exterior doors

    Closed, but not sealed or taped.

  • Fireplace and stove

    Their doors closed.

  • Dampers

    Exhaust, intake and flue dampers closed.

  • Interior doors

    Open where they are installed.

  • Heating and cooling

    Off.

  • Registers

    Supply and return registers fully open where they are installed.

Blower door fan sealed into the front doorway of a new house, seen from outside

Booking the Blountstown retest

The retest date goes after the corrections are finished, not while work is still going on in the house. Tape, plastic or covers put over a register, fan or vent during that work come off before the retest. On a job with several houses, only the house that read high is tested again, and the others keep their own readings. The site contact needs the retest date as well as the builder.

Blower door fan sealing the front door of a new house, seen at an angle

Keeping the house the same between tests

Between the first test and the retest, the only change to the shell should be the corrections. A new opening made in the meantime, for a late line, a vent or outdoor wiring, is part of the second reading. Any trade with work still to do that crosses the outside walls, ceiling or floor needs to finish it before the retest, so the second number describes the house as it will stay.

Blower door fan set up in a hallway doorway of a new home

Several houses

Booking several Blountstown houses on one job

Builders can book several Blountstown houses in one request, one line per house.

  • Dates per house

    Each house gets a test date that follows its own ready date.

  • Spec houses

    A house with no buyer yet is booked like any other, since the test is tied to the house.

  • Getting in

    Any gate code or lockbox for each house, on its own line.

  • Houses in other towns

    Houses elsewhere in the counties we serve can go in the same request, each under its own street address.

New single-story house with the outside finished and the yard not yet landscaped

Crews in the house on retest day

Painters, flooring crews and cabinet installers can keep at it during a Blountstown retest, provided the house stays in the test-day set-up and the doorway with the fan in it is left alone until the test ends. Work at other houses on the job has no effect on the reading. Whoever opens the house that day is the one to pass this on to the crews.

Newly built white farmhouse-style home with a metal porch roof and fresh sod

No need to wait

Work that can go ahead before the retest

Anything that stays inside the rooms or outside the house altogether leaves the reading as it is.

  • Finishes

    Paint, flooring, trim, cabinets and countertops.

  • Fixtures

    Light fixtures on boxes that are already in, and shelving inside closets.

  • Outside

    Driveway, walks, landscaping and gutters.

Hallway of a newly finished house

Booking

What to send with a Blountstown booking

  • Where

    The street address of the house.

  • Permit

    The building permit number for the house.

  • When

    The ready date for a first test, or the date the corrections will be done for a retest.

  • Who

    A name and phone number for the person who opens the house.

Newly built single-story home with fresh sod and a new driveway

How the test is run

A fan is fitted in an exterior doorway, in a frame and panel that close off the rest of the opening. The fan holds the house at the test pressure, and the air it has to move to do that is the leakage. Every heated and cooled room is measured at once, so the test cannot read one room or one wall on its own, and a retest reads the entire shell again.

Empty living room of a newly finished house

The limit

The limit for a new Blountstown house

Section R402.4.1.2 of the 2023 Florida Building Code, Energy Conservation, allows a new house no more than 7 air changes per hour at 50 pascals in Climate Zones 1 and 2. Table R301.1 places Calhoun County in Climate Zone 2.

  • Exactly 7

    A reading of 7.0 is within the limit, since the code allows no more than 7.

  • Any size of house

    A small house and a large one are held to the same 7, because the reading is scaled to the volume inside the shell.

Empty kitchen of a newly built house

The boundary

What sits inside the measured boundary

The attic and an attached garage decide where the measured shell runs.

  • Vented attic

    Outside the test. The ceiling below it is the boundary.

  • Attic sealed at the roof deck

    Opened to the house for the test and measured with it.

  • Attached garage

    Outside the test when it is not heated or cooled. The wall and the door between the garage and the living area are part of the boundary, while the big vehicle door is not.

  • A room over the garage

    When it is heated and cooled and the garage is not, its floor is part of the boundary.

Empty garage of a newly built house with a white door and a water heater

Scope

What the Blountstown reading does not measure

The retest, like the first test, measures air leakage through the shell alone.

  • Insulation

    The amount of insulation in the walls, floor and attic is outside the reading.

  • Windows

    Their energy ratings are covered by other parts of the code.

  • Heating and cooling

    The size and efficiency of the system are not measured.

Empty bedroom of a newly finished house

Other services

Other work on the same Blountstown house

Gutters, a garage door and wire shelving for the same house go through the same phone number and form.

  • Gutters

    Seamless gutters for houses and commercial buildings, with downspouts moved or added above ground.

  • Garage doors

    Repair, new doors measured to the opening, and commercial and roll-up doors.

  • Wire shelving

    Closets, pantries, laundry rooms and garages, supplied and installed.

New seamless gutter run installed along a residential roofline
Newly built stucco home with a white garage door and a new concrete driveway

Same county

Blower door tests in other Calhoun County towns

Newly built two-story home with fresh sod and a new driveway

What to expect

From booking to result in Blountstown

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Empty laundry room with washer hookups in a newly finished house

FAQ

Blountstown blower door questions

Have another question? Call (850) 819-6031.

Will adding insulation bring the number down?
No, not by itself. The reading measures air moving through gaps, and fibrous insulation laid over a gap still lets air pass.
Is the floor of a raised house part of the retest?
Yes. When the house sits on piers or over a crawl space that is not heated or cooled, its floor is part of the shell every time it is tested.
What does 50 pascals equal?
50 pascals is 0.2 inches of water gauge. The code gives both figures for the same test pressure.
Does the heating and cooling system need to be finished?
No. What matters is that the openings for its lines and ducts have been made.
What does air changes per hour mean?
It is how many times the air inside the house would be replaced by outside air in one hour at the test pressure.
Can dry drain traps raise the reading?
Yes. A trap with no water in it leaves an open path from the drain to the plumbing vent on the roof. Running water into each sink, tub and shower before the retest refills them.

Get a quote

Request a Blower Door Test in Blountstown

Use the form to book a first test or a retest on a Blountstown house.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Hallway of a new house with an attic access hatch in the ceiling

Your information is used to respond to this request. See our Privacy Policy.