Blower Door Testing in Caryville, Florida

What the test measures on a new Caryville house, from the attic down to the wall shared with the garage.

Blower door fan set in a red panel across the front doorway of a new house

Blower door tests for new houses in Caryville

Big Bend Services, Inc. tests newly built houses in Caryville, ZIP code 32427, for air leakage under the Florida energy code. The test measures how much air gets through the boundary around the rooms you heat and cool, and where that boundary runs on your plan decides which parts of the house count.

Call (850) 819-6031 on a weekday between 7:00 AM and 4:00 PM, or send the form on this page.

Newly built single-story home with fresh sod and a new driveway

The boundary

Which parts of a Caryville house are measured

  • Vented attic

    Outside the boundary. The ceiling below it is the line that gets measured.

  • Sealed attic

    Inside the boundary, which then runs along the underside of the roof.

  • Attached garage

    An unheated, uncooled garage is outside. The wall and the door between it and the house are part of the boundary.

  • Open porches

    A porch open to the weather is outside. The house wall behind it is an exterior wall like any other.

  • Screened porches

    Outside as well, unless the porch is closed in and heated or cooled.

Blower door fan sealing the front door of a new house, seen at an angle

Vented attic

Openings in a ceiling under a vented attic

  • Attic hatch or stair

    The access is a large opening in the ceiling. It needs weatherstripping and a lid or stair door that closes firmly.

  • Light cans and fan housings

    Recessed lights and bath fans sit in cutouts in the ceiling, with a gap around each edge.

  • Top plates

    Wires and pipes running up through the top of a wall into the attic leave openings in the plate.

  • Soffits and dropped ceilings

    A soffit built over kitchen cabinets or a dropped ceiling in a hall can open into the attic above if it was not closed off at the top.

  • Ceiling duct boots

    Where a supply duct ends at a ceiling register, the gap between the boot and the drywall opens straight into the attic.

  • Flue chases

    The framed box around a fireplace flue can run from the attic down inside the walls below.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

When the attic is sealed at the roof deck

Some plans put the insulation and the air seal on the underside of the roof deck instead of on the attic floor. On test day that attic is opened to the rooms below and measured with them, so the places where the roof deck meets the walls, the gable ends and the eaves become the edges that count, and the ceiling hatch and light cans no longer do.

Mention a sealed attic when you book.

Blower door fan set up in a hallway doorway of a new home

Reading the boundary off your plan

The plan already shows where the boundary runs. Look at where the insulation is drawn: on the attic floor or under the roof deck, in the wall between the garage and the house, under a room that sits over open air. The air boundary the test measures follows that same line, and every space the insulation wraps is inside it.

Where the drawings leave it unclear, such as a storage room off the garage or a closet under the stairs to a bonus room, ask whether that space is heated and cooled.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

Upper floors

Edges on two-story and bonus-room plans

  • The band between floors

    Where the upper floor framing meets the outside walls, the joint runs all the way around the house.

  • Stair walls against the attic

    A stair wall that backs onto attic space needs the same air seal as an outside wall.

  • Cantilevered floors

    A floor that hangs past the wall below has outside air under it.

  • Tray ceilings

    A tray steps up into the attic, and its short vertical faces are part of the boundary along with the flat parts.

Newly built two-story home with fresh sod and a new driveway

Attached garage

Where the garage wall can leak

  • The door into the house

    Weatherstripping on the sides and top and a seal along the bottom close the gaps around it.

  • Pipes and wires through the shared wall

    A water line, a gas line or wiring that passes from the garage into the house leaves an opening in that wall.

  • Outlets on the shared wall

    Electrical boxes on either face of that wall are openings in it.

  • The overhead door

    The big garage door is outside the boundary and has no part in the reading.

  • A hatch in the garage ceiling

    With a vented attic, it opens from one outside space to another and is not part of the house boundary.

Empty garage of a newly built house with a white door and a water heater

The floor

The bottom of the boundary

  • On a slab

    Pipes and conduit that come up through the concrete, and the joint where the bottom plate of each outside wall sits on the slab.

  • Over a crawlspace

    The subfloor and every opening cut in it for plumbing, wiring or a floor register.

  • Under the tub

    The opening cut in the floor or slab for a tub drain is hidden once the tub is set.

Hallway of a new house with an attic access hatch in the ceiling

Finishes

What can wait until after the Caryville test

The reading depends on the openings through the shell, not on the surfaces inside it.

  • Paint and trim

    Wall paint, baseboards and door casings go over surfaces that are already closed in.

  • Flooring

    Tile, wood, vinyl or carpet laid over the slab or subfloor.

  • Cabinets and countertops

    These can be set before or after the test. Any pipe or wire behind them that passes through an outside wall does need to be in.

  • Light trims

    The trim ring on a recessed light is a finish. The housing and the ceiling around it are not.

Empty kitchen of a newly built house

The limit and a retest

Caryville is in Climate Zone 2, where section R402.4.1.2 of the Florida Building Code, Energy Conservation, 8th Edition (2023), allows up to 7 air changes per hour at 50 pascals. A house over that has its leaks corrected and is tested again, with the attic, the door from the garage and the registers set exactly as they were for the first test, so the two readings can be compared.

Blower door fan sealed into the front doorway of a new house, seen from outside
Newly built white farmhouse-style home with a metal porch roof and fresh sod

Same county

Blower door tests elsewhere in this county

Empty laundry room with washer hookups in a newly finished house

What to expect

How a Caryville test is booked

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built stucco home with a white garage door and a new concrete driveway

FAQ

Caryville attic, garage and finish questions

Have another question? Call (850) 819-6031.

Is a bonus room over the garage inside the test?
Yes, if it is heated and cooled. Its floor then separates living space from the garage, so gaps in that floor count, along with the knee walls and the ceiling around the room.
Does a detached garage or shop get tested?
No. A building that stands apart from the house has no connection to its air, so the fan in the house never reaches it and it plays no part in the result.
Does attic insulation have to be in before the test?
On a vented attic, loose insulation over the ceiling does not stop air, so whether it is blown in yet makes no difference to the reading. On a sealed attic, the air seal under the roof deck has to be finished before the test date.
Do the kitchen appliances need to be in?
The appliances themselves do not matter. What matters is that any vent they use, such as a range hood duct or a dryer vent, has been run through the wall or roof. A refrigerator, dishwasher or washer has no bearing on the reading.
Should the door from the garage be open or shut?
Shut and latched, like the front and back doors. Leaving it open would join the garage to the house, adding its volume and all of its gaps to the reading.

Get a quote

Request a Blower Door Test in Caryville