Blower Door Testing in DeFuniak Springs, Florida

Blower door tests on new houses in DeFuniak Springs, and the energy code exception for additions.

Blower door fan set in a red panel across the front doorway of a new house

New homes and additions in DeFuniak Springs

Big Bend Services, Inc. runs blower door tests on newly built houses in DeFuniak Springs, in ZIP codes 32433 and 32435. The Florida energy code requires the test on a new house, and the same code section sets an exception for additions and alterations.

Call (850) 819-6031 or send the form. Our office in Wewahitchka takes requests Monday to Friday, 7:00 AM to 4:00 PM.

Newly built single-story home with fresh sod and a new driveway

Additions

Additions and alterations under the energy code

Section R402.4.1.2 of the 2023 Florida Building Code, Energy Conservation, does not require the test for additions, alterations, renovations or repairs to less than 85 percent of the building thermal envelope. That envelope is the layer between the heated and cooled rooms and the outside: the outside walls, the ceiling under a vented attic and the floor.

  • A room added to one side

    The new walls, ceiling and floor become a share of the envelope, measured against the whole.

  • A garage turned into living space

    Heating and cooling the garage brings its walls, its ceiling and the old door opening inside the envelope.

  • A porch closed in and air conditioned

    Its walls and ceiling join the envelope. An open or screened porch stays outside it.

  • Work inside only

    Kitchens, baths and floors redone without touching the outside walls, ceiling or floor leave the envelope as it was.

Empty garage of a newly built house with a white door and a water heater

Booking

What to send with a DeFuniak Springs booking

Four details set a test date on a new house, whether you call or use the form. The owner of a new house can book directly, without going through a contractor.

  • Address

    The street address of the house.

  • Permit number

    The building permit for the house.

  • Ready date

    The date the house will be ready for the test.

  • Site contact

    The person who opens the house on the day, with any gate code or lockbox needed to get in.

  • Several houses

    A line with these four details for each one, since each house is tested on its own.

Torsion springs on the steel shaft above a closed garage door

When a new DeFuniak Springs house is ready

The code allows the test any time after every opening through the thermal envelope has been made. On a new house, that means the plumbing vents and hose bibs, the outside lights and outlets, the electrical service, the refrigerant and condensate lines, the dryer vent, the range hood duct, the bath fans and the attic hatch are all in. An opening made after the test is not part of the reading, so trades with late work need to know the test date.

New single-story house with the outside finished and the yard not yet landscaped

The boundary

Where the measured boundary runs on a new house

The attic and an attached garage decide how much of the building sits inside the test.

  • Vented attic

    The attic sits outside the test, and the ceiling below it is the boundary.

  • Attic sealed at the roof deck

    The attic is opened to the house for the test and measured with it.

  • Attached garage

    Outside the test when it is not heated or cooled. The wall and the door between the garage and the living area are measured as part of the boundary.

  • A room over the garage

    When it is heated and cooled and the garage is not, the floor between them is part of the boundary.

Blower door fan sealing the front door of a new house, seen at an angle

Test day

Setting the house up in DeFuniak Springs

These conditions hold for as long as the test runs.

  • Outside

    Exterior windows and doors closed, but not sealed or taped. An open window adds a gap the house will not have, and tape hides one it will have.

  • Fireplace and stove

    Their doors closed.

  • Dampers

    Exhaust, intake and flue dampers closed, as they sit when the fans are off.

  • Inside

    Interior doors open where they are installed, so every room reaches the same pressure.

  • Equipment

    Heating and cooling turned off, since a running air handler pushes its own air against the fan.

  • Registers

    Supply and return registers fully open where they are installed.

Blower door fan sealed into the front doorway of a new house, seen from outside

How the test is run on a new house

A fan goes into an exterior doorway, set in a frame and panel that fill the rest of the opening. It moves air through the doorway until the house is held at the test pressure, and the amount of air it has to move to hold that pressure is what the reading is built from.

Blower door fan in a red panel beside a doorway with a gauge on a tripod

The limit a new DeFuniak Springs house has to meet

Section R402.4.1.2 allows a new house no more than 7 air changes per hour at 50 pascals in Climate Zones 1 and 2, and Table R301.1 of the code places Walton County in Climate Zone 2. A reading at or below 7 is within the limit. Above 7, the leaks are corrected and the house is tested again under the same conditions as the first test.

Blower door fan set up in a hallway doorway of a new home

Scope

What a DeFuniak Springs reading leaves out

The reading is about air leakage through the shell alone.

  • Insulation

    How much insulation is in the walls and attic is covered elsewhere in the energy code.

  • Windows

    Window and glass door energy ratings are not part of it.

  • Equipment

    The size and efficiency of the heating and cooling system are not rated.

Extension spring and pulley along the side track of a garage door

Crews in the house on test day

Other work can go on around a DeFuniak Springs test as long as the house stays in the test-day set-up and nobody uses the doorway the fan is fitted in. Tell the trades on site the test date when it is set, so the day is planned around it, and let the person opening the house know which crews will be there.

Blower door fan in a red frame across an interior doorway with a gauge on a tripod beside it

Finish work

Work that does not hold up the test

Work that stays inside the envelope, or outside the house altogether, leaves the reading as it is, so these crews can work before the test or after it.

  • Paint and flooring

    Wall paint, tile, wood and carpet go on surfaces already in place.

  • Trim, cabinets and countertops

    All of it sits inside the rooms.

  • Driveway and landscaping

    Both are outside the house.

Empty kitchen of a newly built house

Other services

Other work for a new DeFuniak Springs house

Gutters, a garage door and wire shelving for the same house are booked through the same office.

  • Gutters

    Seamless gutters formed on site to each roof edge, scheduled around the builder.

  • Garage door

    A new door measured to the opening, with a new opener if wanted.

  • Wire shelving

    Closets, pantry and laundry room, supplied and installed.

Single-story home with three white garage doors side by side
Newly built stucco home with a white garage door and a new concrete driveway

Same county

Blower door tests in nearby Walton County towns

Empty living room of a newly finished house

What to expect

Booking a test in DeFuniak Springs

  1. 1

    Send the build details

    Address, permit number and when the house will be ready.

  2. 2

    Test booked

    We give you a date for the test.

  3. 3

    Test run

    The house is tested once it is ready.

  4. 4

    After a failed test

    Corrections are made and the house is tested again.

Get a Quote

Newly built white farmhouse-style home with a metal porch roof and fresh sod

FAQ

DeFuniak Springs blower door questions

Have another question? Call (850) 819-6031.

What does air changes per hour mean?
It is how many times the air inside the house would be swapped for outside air in one hour at the test pressure.
Is the floor of a raised house part of the test?
Yes. When the house sits on piers or over a crawl space that is not heated or cooled, the floor is part of the shell.
Is the limit different in winter or summer?
No. The code sets one limit whatever the season.
What does 50 pascals equal?
50 pascals is 0.2 inches of water gauge. The code gives both figures for the same test pressure.
Does the reading say where the leaks are?
No. The result is one number for the whole shell. It shows how much air gets through, not where.
Can the test be run before the drywall is up?
Yes. A test before drywall reads the shell as it stands that day, so whatever stops air on that plan, such as sheathing, house wrap or sealed top plates, has to be complete by then.

Get a quote

Request a Blower Door Test in DeFuniak Springs

Use the form to book a test on a new DeFuniak Springs house, and the office will follow up.

(850) 819-6031

511 S Highway 71, Wewahitchka, FL 32465
Monday to Friday, 7:00 AM to 4:00 PM

Empty bedroom of a newly finished house

Your information is used to respond to this request. See our Privacy Policy.